Home > Products > Spectroscopy: UV-Vis-NIR Accessories
SL4-DT Deuterium and Tungsten Light is a miniature Deuterium and Tungsten halogen light source that covers the 200-2300nm range in a single light source for spectroscopy measurements. Its high output power enables use for reflectance measurements, where other low power light sources like SL5-DT are too weak.
The miniature size of 72 x 40 x 90mm makes it a perfect match for StellarNet miniature spectrometers: D-alpha line (654nm) eliminated in deuterium source. The deuterium and halogen lamps can be individually turned on/off and have a front and panel shutter control. The combination of both lamps into one small enclosure reduces complexity and can be connected to the BP2 battery pack for field applications.
NOTE: This product is only recommended for applications that require high output power (e.g. reflectance), portability, and small size.
Send EnquiryThe high power SL1-Filter Halogen lamp and the SL3 Deuterium lamp with DCX
The F400-YBNIRUV-SR is an armoured 400µm fibre optic Y cable bundle that is 0.5 metre, solarisation resistant, and is specially designed to connect the SL1 and SL3 lamps.
D-alpha line (654nm) eliminated in deuterium source by adding a U330 filter to the nosecone of the SL3 light source.
NOTE: This product is recommended for applications that require high output power (e.g. reflectance) and do not require demanding portability or size characteristics. Bulb life and robust design are the main advantages over SL4.
Send EnquiryWarsash Scientific offer a variety of low cost integrating spheres and accessories for photometric and radiometric applications. These spheres are available in a variety of sizes to offer customers the most flexibility when choosing a sphere for their application. The spheres are extremely robust yet are surprisingly lightweight, compact, and easy to operate.
StellarNet integrating spheres, when coupled with a StellarNet spectrometer, provide NIST
The wide range of miniature spectrometers and complete line of light sources, optical fibres, and sampling accessories, from StellarNet, combine with software development tools to enable easy integration of various optical sensing techniques into end user systems.
These spectrometers are designed rugged with no sockets or moving parts inside an aluminium enclosure for extreme durability to suit virtually any application or environment. Internal detectors are bolt mounted while gratings and other optical components are mill-bonded resulting in vibration tolerant and shock proof alignment. The spectrometers are powered via high-speed USB2 interface.
Send EnquiryCosine Receptors couple to fibre optic cables and collect light with an 180° field of view using demountable diffusers. A perfect cosine response provides accurate absolute intensity when multiple lights are measured at same time. Cosine receptors provide relative and absolute spectral intensity measurements, for emissive colour applications, and for evaluation of light sources such as the Sun, Lamps, LED
Single strand, multimode fibre optic cables are available with SMA 905 connectors, 6.35mm (¼") diameter. steel mono-coil armour with black PVC jacket. Sizes include 400, 600, or 1000µm core diameters. Standard lengths are 1 and 2 metres.
Custom lengths are available with a minimum price of a 1 metre fibre (extra delivery time also).
F400-UVVis-SR, F600-UVVis-SR, and F1000-UVVis-SR-1 Solarisation resistant fibres available for deep UV applications below 400nm available in all diameters.
F400-VISNIR, F600-VISNIR, and F1000-VISNIR-1 are low OH fibres (400-2200 nm) are needed for VIS-NIR applications. They offer lowest possible internal light attenuation. Intended for applications with long fibre lengths, available in all diameters.
Specialty fibres available for various applications: Y-cables to couple two spectrometer systems, Y-bundled cables to couple two light sources, 1 to 3 splitter cables, and all types of custom fibres to meet your application.
Send EnquiryBP1 is a Lithium-Ion Battery Pack with 5400mA/h, 2 x 5V out. Ultimate Portability using the light weight BP1/BP2 battery pack for field work. Long Life rechargeable battery pack BP1 provides over 5 hours of continuous spectral acquisition for RED-Wave NIR
BP2 is a Lithium-Ion Battery Pack with7400mA/h, 2 x 5V and 2 x 12V out. BP2 adds on 2 additional 12V power outputs to operate 2 spectrometers and 2 light sources. The BP2 can power the SL1 and the SL5 lamps.
Instrument Case is watertight, crushproof, and dust proof. It has easy to open double throw latches and padlock protectors. Pack your StellarNet spectroscopy equipment for field measurements. Dimensions are 425 x 284 x 155mm (6.75" x 11.18" x 6.12").
Send EnquiryRS50 is a 50mm diameter white reflectance standard made of Halon. It is used to take reference measurements using the R400 Reflectance Probe. The white standard will reflect >97% of the light from 300-1700nm.
TF-STD1 Thin Film standards for thickness measurement verification. Includes Si substrate for reference with 2 additional substrates with 100nm and 1000nm thickness of SIO2. Additional thickness standards (10nm and 10,000nm) can be added to the set.
Send EnquiryFull spectrum chemometric analysis for multiple components can now be performed using the ChemWiz® Analyser Development Kit (ADK). This software toolkit, when combined with StellarNet spectrometer instrumentation and SpectraWiz operating software, enables rapid development of complex analysers needed to provide custom measurement solutions for many applications.
Send EnquiryThis compact, USB-powered lamp features a SMA 905 connector for easy coupling in optical fibres. Via fibres, the lamp can be connected to a sample holder, reflection probe or to an integration sphere. It features a smart power control for high lamp stability, a mechanical variable shutter for power output control and an integrated cuvette or filter holder. The USB-powering makes this lamp ideal for on the field spectral measurements.